Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Vasc Bras ; 19: e20190124, 2020 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-34178067

RESUMO

Occlusions and severe stenoses of the innominate artery (brachiocephalic trunk) are rare and present with a wide variety of clinical manifestations, with hemispheric, vertebrobasilar and right upper limb ischemic symptoms. The most common cause is atherosclerosis. Duplex scanning may show right vertebral artery flow reversal, diminished subclavian flow, and several patterns of right carotid flow disturbance, including slow flow, partial flow reversal during the cardiac cycle and even complete reversal of flow in the internal carotid artery, which is a very uncommon finding. Herein, the authors describe the case of a female patient who was a heavy smoker, had severe stenosis of the brachiocephalic trunk, and had episodes of collapse. Besides the subclavian steal and partial flow reversal in the common carotid artery, duplex scanning also showed high-velocity reversed flow in the internal carotid artery during the entire cardiac cycle, a finding that is not reported in the literature at this magnitude.

2.
J. vasc. bras ; 8(2): 103-111, jun. 2009. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-521362

RESUMO

CONTEXTO: O uso do pericárdio bovino como remendo na endarterectomia de carótida é uma alternativa à veia safena magna. As vantagens do pericárdio incluem facilidade de obtenção, menor tempo operatório e principalmente menor índice de ruptura. OBJETIVO: Avaliar a resistência tensional do pericárdio bovino tratado com glutaraldeído e compará-la com a da veia safena magna. MÉTODOS: Os remendos de pericárdio bovino (grupo I, n = 20) e de veia safena magna (grupo II, n = 20) foram recortados em dimensões iguais (50 x 5 mm) e preparados de modo habitual a sua utilização. Os grupos foram submetidos a ensaio de tração e comparados em relação a força de ruptura, força máxima e tensão de ruptura utilizando-se o teste t de Student. A correlação da espessura do remendo com a força de ruptura também foi analisada utilizando-se o coeficiente de correlação linear de Pearson. RESULTADOS: Os parâmetros força de ruptura e força máxima foram significativamente maiores no grupo dos remendos de pericárdio bovino: 1,97 versus 1,36 kgf (p = 0,001230) e 2,27 versus 1,51 kgf (p = 0,0001087), respectivamente. A tensão de ruptura média para o material pericárdio bovino também foi maior (193,99±43,05 versus 49,19±22,96 kgf/cm², p = 7,603e-16) do que na veia safena. A correlação entre a espessura e a força de ruptura foi considerada moderada (r = 0,5032993) para o pericárdio bovino e baixa (r = 0,3062166) para o grupo da veia safena. CONCLUSÃO: Os autores concluem que a resistência do pericárdio bovino à ruptura foi considerada adequada neste estudo, e é significativamente maior que a da veia safena magna, retirada da região da coxa. Além disso, a espessura do remendo em ambos os grupos não apresenta boa correlação com sua resistência a ruptura.


BACKGROUND: Carotid endarterectomy using bovine pericardium is an acceptable alternative to great saphenous vein patch. Bovine pericardium is easily obtained and provides a shorter operative time and lower rupture rate. OBJECTIVE: To evaluate rupture resistance of glutaraldehyde-treated bovine pericardium patch in comparison with great saphenous vein patch. METHODS: The sample was divided into two groups: bovine pericardium patch (group I, n = 20) and great saphenous vein patch (group II, n = 20). Both bovine pericardium and saphenous vein patches were prepared in the same dimensions (50 mm x 5 mm) and tested using standard procedures. The patches were tested in the longitudinal axis until the point of material failure. The following parameters were addressed: failure force, ultimate force and failure stress. Statistical analysis was conducted using the Student t test and Pearson's linear correlation. RESULTS: Failure force and ultimate force parameters were significantly higher in the bovine pericardium patch group: 1.97 vs. 1.36 kgf (p = 0.001230) and 2.27 vs. 1.51 kgf (p = 0.0001087), respectively. Mean failure stress in the bovine pericardium patch group was also significantly higher than that in the great saphenous vein group (193.99±43.05 vs. 49.19±22.96 kgf/cm², p = 7.603e-16). The correlation between thickness and failure force was considered moderate (r = 0.5032993) for the bovine pericardium group and low (r = 0.3062166) for the great saphenous vein group. CONCLUSION: The failure stress related to the bovine pericardium group was considered appropriate in this study, and was significantly higher than that observed in the great saphenous vein group. In addition, patch thickness in both groups did not show a good correlation with rupture resistance.


Assuntos
Endarterectomia das Carótidas/métodos , Endarterectomia das Carótidas , Pericárdio/fisiologia , Veia Safena/fisiologia
3.
J. vasc. bras ; 8(1): 86-88, jan.-mar. 2009.
Artigo em Português | LILACS | ID: lil-514855

RESUMO

O transplante hepático vem progressivamente apresentando melhores resultados e maior preocupação com a qualidade de vida dos pacientes. As varizes dos membros inferiores são comuns na população e causam sintomas em boa parte dos casos, comprometendo a qualidade de vida. Em pacientes com boa condição clínica e funcionamento normal do enxerto, o tratamento cirúrgico das varizes de membros inferiores pode ser a opção com resultado mais eficaz e duradouro. Os autores relatam dois casos de pacientes que haviam sido submetidos a transplante hepático e apresentavam varizes sintomáticas de membros inferiores, e foram submetidos a cirurgia de varizes após liberação pela equipe de transplante hepático. As operações ocorreram sem intercorrências, com bom resultado no seguimento. A cirurgia de varizes dos membros inferiores pode ser realizada com segurança em pacientes receptores de transplante hepático, sendo uma opção eficaz e duradoura no tratamento da insuficiência venosa crônica nesses pacientes.


Liver transplantation is having progressively better outcomes, and quality of life is being more often addressed. Varicose veins of the lower limbs are common in the general population and cause symptoms in a significant number of cases, impairing quality of life. For patients in good clinical condition, with adequate graft function, surgical treatment for varicose veins of the lower limbs can be a safe option, with more effective and longer lasting outcomes. The authors report two cases of liver transplant recipients who had symptomatic varicose veins of the lower limbs and were submitted to varicose vein surgery following authorization from the liver transplantation team. Operations were uneventful, with good follow-up results. Surgery for varicose veins of the lower limbs can be safely performed in liver transplant recipients, and it is an effective and long lasting treatment for chronic venous insufficiency in these patients.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Insuficiência Venosa/cirurgia , Insuficiência Venosa/complicações , Transplante de Fígado/efeitos adversos , Transplante de Fígado/mortalidade , Varizes/cirurgia , Varizes/complicações , Extremidade Inferior/cirurgia , Qualidade de Vida/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...